Electrical Testing, London

Electrical Installation Condition Report London.

Qualified electrical inspections across all London boroughs. Legal requirement for landlords. Certificates issued the same day as inspection. From £99 for 1–3 bed properties. Part of GMAS Group's wider refurbishment and landlord-compliance service.

£99
From, 1–3 bed
Same day
Certificate issued
All London
Boroughs covered
Pricing
Fixed prices, no hidden charges. Congestion charge may apply in central London.
1–3 bedroom property
Most common, covers all circuits and distribution board
£99
4–5 bedroom property
Extended inspection for larger homes with additional circuits
£109
HMO / multi-let
Includes all individual units and communal areas
From £149
Commercial property
Bespoke quote based on size and circuit count
POA
Free quote
Book now →

Congestion charge and parking costs may apply for central London postcodes.

What is an EICR?

What is
an EICR?

An Electrical Installation Condition Report (EICR) is a formal document produced after a thorough assessment of the electrical installations within a property. It identifies any deficiencies against the UK standard for electrical safety, BS 7671.

The report grades any issues found using a coding system: C1 (immediate danger, must be fixed before the certificate is issued), C2 (potentially dangerous, must be rectified within 28 days), C3 (improvement recommended but not legally required) and FI (further investigation required).

A satisfactory EICR is valid for 5 years for rental properties and is recommended every 10 years for owner-occupied homes. Mortgage lenders increasingly require an EICR where electrical concerns are flagged in a home survey.

Why you need it

Why London
homeowners choose us.

Legal requirement for landlords

Since 1 April 2021, all landlords in England are legally required to have a valid EICR. New tenancies require one before the tenancy starts. Existing tenancies require renewal every 5 years. Failure to comply carries fines of up to £30,000.

Required for home purchases

Mortgage lenders and solicitors frequently require an EICR where a home survey flags electrical concerns. We can carry out same-day inspections to keep your purchase on track.

Insurance compliance

Many home and landlord insurance policies require up-to-date electrical certification. An EICR protects your policy validity as well as your tenants.

Peace of mind

For owner-occupiers, an EICR gives confidence that your home's electrics are safe, particularly important in pre-1970s properties or after any significant renovation work.

What's included

Everything in
one visit.

Consumer unit & fuse board
Full inspection of the distribution board, MCBs, RCDs and bonding.
All circuits tested
Every lighting, ring main and radial circuit tested for continuity, insulation resistance and polarity.
Sockets & switches
All fixed outlets checked for correct wiring, earthing and condition throughout the property.
Earthing & bonding
Main and supplementary bonding verified to current BS 7671 standard.
Fixed wiring inspection
Visual inspection of all accessible wiring, cable routes and installation condition.
Same-day certificate
Digital EICR certificate emailed to you the same day as the inspection.
C1 & C2 fault identification
All dangerous items clearly coded and explained. Remedial works available on the same visit where possible.
Detailed written report
Full written report with photographic evidence, observations and recommended remedial actions.
Coverage
Areas we cover
Covering all London boroughs
Shepherd's BushHammersmithFulhamKensingtonChiswickWhite CityNotting HillActonEalingChelseaPaddingtonSouthallHounslowBrentfordPutneyWandsworthHarrowWembley+ all London boroughs
From the blog

Guides related to
this service.

Common questions

Everything
you need to know.

Can't find what you're looking for? Call us and we'll answer any question.

Call 07498 597339
How long does an EICR take?+
Most 1–3 bed properties take 2–4 hours. A 4–5 bed property typically takes 3–5 hours. HMOs and commercial properties vary depending on circuit count, we'll give you a time estimate when booking. Our engineer will need access to all rooms, the loft if accessible, and the consumer unit.
What happens if my EICR fails?+
An EICR doesn't technically 'fail', it receives a Satisfactory or Unsatisfactory outcome. If unsatisfactory, the report will list C1 (immediate danger) or C2 (potentially dangerous) items that must be rectified. C1 items must be fixed before the certificate is issued. C2 items must be addressed within 28 days. GMAS Group can carry out all remedial works and re-issue the certificate on the same day where possible.
Do tenants need to be present during an EICR?+
No, the engineer needs access to the property but tenants do not need to be present. Many landlords arrange access directly. We can also liaise with tenants directly if you prefer. We carry ID and certification and will handle the appointment professionally.
Can you do an EICR and remedial works on the same day?+
Yes, in most cases. If C1 or C2 faults are identified, our engineer carries a stock of common materials and can often carry out straightforward remedial works immediately. More complex remedial works such as consumer unit replacements may require a follow-up visit, which we book at the earliest available slot.
What's the difference between an EICR and a PAT test?+
An EICR covers the fixed electrical installation, the wiring, sockets, fuse board and circuits built into the property. It does not cover portable appliances such as kettles, lamps and white goods, which are checked separately.
Is an EICR the same as an electrical safety certificate?+
Yes, an EICR is the formal term for what is often called an electrical safety certificate. It is the document required by law under the Electrical Safety Standards in the Private Rented Sector (England) Regulations 2020. The terms are used interchangeably.
Book now

Ready to
book?

We respond within the hour. Certificates issued the same day as inspection.

Same-day certificates issued on inspection
Qualified & experienced engineers
All London boroughs covered
Book an EICR → Call 07498 597339
Send an enquiry

Prefer to
write to us?

On the day

What actually happens during the inspection.

An EICR is an inspection and a set of measurements, not a look around. The electrician starts at the consumer unit, records what is there and checks the earthing and bonding arrangements, then works through every circuit in the property. Some of the testing is done with the power off, which is why the supply is switched off for part of the visit, and some is done live once the dead tests have passed.

For a typical one to three bedroom flat or house the electrical testing takes around two to three hours. Larger properties, older installations and anything with a mix of original and added circuits take longer, because every added circuit has to be traced and tested like any other. Where a circuit cannot be safely tested or accessed, it is recorded as a limitation on the report rather than quietly left out.

You do not need to be there for the whole visit, but somebody needs to give access to the consumer unit, the meter, the loft if there is wiring in it, and every room with a fixed outlet. Clearing access to sockets behind furniture before the electrician arrives saves time and keeps the inspection complete.

The testing

The tests behind the certificate.

Every EICR is built on the same sequence of electrical tests set out in BS 7671. These are the measurements that appear on the schedule of test results attached to your report, and they are what separates a real inspection from a visual check.

Continuity of protective conductors

Confirms every earth conductor is connected end to end, so a fault has a path back and the protective device operates.

Ring final circuit continuity

Proves a ring main is a complete ring and has not been broken or wired as a spur on a spur, which is one of the most common faults found in older houses.

Insulation resistance

Measures how well the cable insulation is holding up. Low readings point to damaged cable, damp, or a nail or screw through a run.

Polarity

Confirms live, neutral and earth are the right way round at every point, including switches, so nothing stays live when it is switched off.

Earth fault loop impedance

Measures the resistance of the fault path to confirm the breaker or fuse will trip quickly enough to be safe.

RCD operation

Times how quickly each residual current device trips, and whether it trips at all. A failed RCD on a socket circuit is a common reason for an unsatisfactory result.

Prospective fault current

Establishes the maximum current that could flow in a fault, which determines whether the installed protective devices are rated correctly.

Visual inspection

Accessible wiring, accessories, enclosures and cable routes checked for damage, overheating, unsuitable modifications and missing covers.

The codes

C1, C2, C3 and FI, in practice.

Every observation on an electrical installation condition report carries a code, and the codes decide whether the report is satisfactory. A report is unsatisfactory if it contains any C1, C2 or FI. C3 items alone do not make it unsatisfactory.

C1, danger present

Something on the installation could cause injury now. Exposed live parts, a broken accessory with conductors showing, or a circuit with no earth. The electrician will make it safe on the day, either by isolating the circuit or fitting a temporary cover, and it is recorded as made safe on the report.

C2, potentially dangerous

Not dangerous while everything is intact, but dangerous if a fault occurs. Missing earthing on a lighting circuit, no RCD protection where it is now required, or a damaged cable in a concealed run. C2 items are the most common reason a property fails, and they have to be put right for the report to become satisfactory.

C3, improvement recommended

The installation complies with the standard it was built to, but not with the current one. A plastic consumer unit in a flat, or no RCD on a circuit that did not need one at the time. Nothing has to be done. It is a note for when the installation is next altered.

FI, further investigation

The electrician has found something that cannot be resolved within the scope of the inspection, often a circuit that cannot be traced or a reading that does not make sense. An FI makes the report unsatisfactory until it is followed up, so it is worth dealing with rather than filing.

Unsatisfactory results

What happens if the report fails.

An unsatisfactory report is not a disaster and it is more common than people expect, particularly in properties that have been extended, converted or rewired in stages. The report lists each coded observation with its circuit and location, so the remedial work is defined rather than open ended.

We price the remedial work from the report itself, item by item, so you can see what is legally required and what is only recommended. Most failures are resolved by replacing a consumer unit, adding RCD protection, correcting earthing and bonding, or repairing a small number of circuits. Where a property genuinely needs more, the full house rewire and consumer unit replacement pages set out what that involves.

Once the work is done, the circuits affected are retested and the certificate is issued. For landlords the 28 day clock for remedial work runs from the date of the report, so the sooner the remedial quote is agreed the easier that deadline is to meet.

Landlords

The legal detail, plainly.

The Electrical Safety Standards in the Private Rented Sector (England) Regulations 2020 apply to all tenancies in England. In short, the electrical installation must be inspected and tested at least every five years by a qualified person, and the resulting report has to reach the right people within set times.

A copy goes to the existing tenant within 28 days of the inspection, to a new tenant before they take occupation, and to a prospective tenant within 28 days of a written request. The local authority can ask for a copy and must receive it within seven days. Where the report requires remedial work, it must be carried out within 28 days, or sooner if the report specifies a shorter period, and written confirmation that it has been completed goes to the tenant and the local authority within 28 days of the work finishing.

Local authorities can serve a remedial notice and arrange the work themselves if a landlord does not, and can impose a financial penalty of up to £30,000 for a breach. If you run a portfolio, the practical answer is to put every property on the same renewal cycle rather than tracking fourteen separate dates. We do that for the landlords and agents we work with, and the agents and landlords page explains how.

Common questions

More questions, answered.

Who is allowed to carry out an EICR?

A qualified person competent in inspection and testing to BS 7671. Our electricians carry the relevant qualifications and their own ID, and the report names the individual who carried out the electrical testing as well as the company.

Will the power be off for the whole visit?

No. The supply is switched off for the dead testing, usually in stages, circuit by circuit where that is practical. Tell us in advance if anything in the property cannot lose power and the electrician will work around it where it is safe to do so.

Is an EICR the same as a PAT test?

No. An EICR covers the fixed electrical installation, meaning the wiring, the consumer unit, sockets and switches. Portable appliance testing covers the plug-in items. Landlords are often asked for both, and they are separate pieces of work.

How long is the certificate valid?

Five years for a rented property, or sooner if the report recommends a shorter interval. Ten years is the usual recommendation for an owner-occupied home, and sooner on change of occupancy.

My survey flagged the electrics. Is an EICR the right thing?

Usually yes. A surveyor will note the age and apparent condition of an installation and recommend a test by a qualified electrician. The EICR is that test, and it turns a vague concern in a report into a defined list of what needs doing.

Can you do the remedial work as well?

Yes. The same electricians carry out the remedial work and the retest, so you are not coordinating two firms and two visits.

What if you cannot access part of the installation?

Anything that cannot be reached or safely tested is recorded as a limitation on the report, with the reason. It is better to state it than to sign off an installation nobody has looked at.